|-------------------------------| | List of changes in CS System: | |-------------------------------| --------------------------------------------------------------------------------------------------- -- CS Version v6.4 --------------------------------------------------------------------------------------------------- - Compatibility for Windows 10 environments - Added compatibility for Endurance series pyrometers - Added the ability to disable alarm for dirty lens - Multiple bug fixes - Known Issues: * Refractory Importer is disfunctional and not translated --------------------------------------------------------------------------------------------------- -- CS Version v6.3.1 --------------------------------------------------------------------------------------------------- - Bug fixes: * Translation mistakes in Daily Report and Historic PRoduction report. Tool buttons are now properly translated * Conversion of kiln length in feet set faulty kiln length in refractory system kiln length * Fixed some focuses of 'Invalid pointer' when freeing ReadScan data structures * 3D kiln displays fake texture when a reading device reads in one or more points at cm 0 or below * Partial Images where reading from the buffers dedicated to final images, thus reading data from the previous image instead of the current data --------------------------------------------------------------------------------------------------- -- CS Version v6.3 - 15.8.2016 --------------------------------------------------------------------------------------------------- v.6.3 - Added fith Scanner support - Config: Redesigned layout in scanner configuration. - Now scanners 3 and 4 will be set to Ethernet by default (fresh installations / updating from versions previous to 6.0 / importing configuration file made in a version previous to 6.0). - Bug fixes: * THR: If ReadScan decides to read data from the read-only database without the need of restoring a THR backup, then it doesn't check if its database structure is the latest. * RCV: If the scanner priority is configured in automatic mode, given a point in the partial thermogram, those scanners without the highest priority on that point are taking their corresponding readings from the buffer that generated the last image, not from the one that is holding the current lap. - Migration to 6.3 for OPC systems OPC nodes have changed. Pyrometers need to be setup again in OPC configurations. --------------------------------------------------------------------------------------------------- -- CS Version v6.2.9 - 28.3.2016 --------------------------------------------------------------------------------------------------- v.6.2.9 - Bug fixes: - Refractory Dialog inputs sanitised - Field ‘Estimated thickness at its end-of-life’ is always editable, even though the record is not in edit or insert modes. - Deneb rises an A/V if ReadScan is stopped while Deneb was displaying a report. - Production report, ‘Thickness’ section: · Column ‘Initial’ always displays the thickness of the associated brick type. Now it shows data only if the zone is new or if a drilling was performed at the end of the previous structure. Otherwise, CS considers that the thickness at the beginning of the new production stage is unknow. · Columns ‘Final (average)’ and ‘Final (est)’ are mixed up. · Values calculated from drillings only used a single operation, instead of an average of them (taking the most recent set of drillings, considering ‘set’ as the group of drillings performed at the end of the same production). - Minor changes: - Now field ‘Thickness’ is not required, and can be cleared. ReadScan will check if this value is non-empty before calculating the thickness estimation for a zone. - Now editor for field ‘Average brick life in days’ has been changed to a standard text editor, so it can be cleared as most of the rest. - Now thickness estimation has been summarized into a single function, and this function has been reviewed in order to prevent any error if any parameter is missing. --------------------------------------------------------------------------------------------------- -- CS Version v6.2.9 RC1 - 1.12.2015 --------------------------------------------------------------------------------------------------- - Bug fixes: - improved data retention when running the kiln below 0.3 Rotations a minute - fixed controlzone loss problem when accessing the software from multiple remote stations - improved UI translations - fixed issue with emailing system causing unecessary messages in the windows event log --------------------------------------------------------------------------------------------------- -- CS Version v6.2.7 - 14.07.2015 --------------------------------------------------------------------------------------------------- - Bug fixes: -All historic review system besides the short and long term images are not functioning with the THR -THR cannot transition from Realtime to Historic -LRM historic trend does not show any rings except ring 1 and 2 --------------------------------------------------------------------------------------------------- -- CS Version v6.2.6 - 11.03.2015 --------------------------------------------------------------------------------------------------- - Bug fixes: -Deneb reports a different kiln RPM than Readscan -OPC. Minimum read Temperature on alarms zones not updated -Config. In the LRM dialog, the "Alarm" tab title shows "Alarmes" --------------------------------------------------------------------------------------------------- -- CS CONFIG Version v6.2.5 - 7.01.2015 --------------------------------------------------------------------------------------------------- -Changes: Unlocked baudrate setting for MI shadow pyrometers. This enables higher Baudrates when MI3 sensors are used. --------------------------------------------------------------------------------------------------- -- Version v6.2.4 - 12.12.2014 --------------------------------------------------------------------------------------------------- -Bugfixes -Output module address field allowed negative values -CS Config retention time guess i removed in favor of THR system -Low alarm ON/OFF disables validity check for high alarm values -Unsynchronized kilns do not match the rotation speed parameter set in oven settings -Invers axis feature changes rotation direction of kiln but not the RCV line -Daily Report would fail under some circumstances -Kiln 3D view fails to function after locking the windows operating system -Activation of new refractory management fails in evaluation mode -Known Issues -Installer Version is 6.2.3 (no need to change) --------------------------------------------------------------------------------------------------- -- Version v6.2.3 - 20/11/2014 --------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- -Bugfixes -Controlzones window is not showing when the menu entry is selected -Prealarm indicators are missing in the Thermograph -Mouse over Thermograph is not showing in status bar -Axis inversion is broken -Floating point deserialisation error trying to show a daily report --------------------------------------------------------------------------------------------------- -- Version v6.2.2 - 27/10/2014 --------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- -Bugfixes -Missing translations -Reference image could not be selected from historic data (THR system) --------------------------------------------------------------------------------------------------- -- Version v6.2 - 17/10/2014 --------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- -Release features -Automatic Client reconnect on short network connection problems -Improved reporting features -Low alarm On/Off switch -Automatic alarm confirmation -THR data management system -Improved real continous view System -90day 3DView / refractorymanagement trial reset; better trial mangement for evaluation installations -Bugfixes -System stability and performance -Translations ( English, German, Catalan, Spanish ) -Addressing SQL 2008 Express R2 SP2 installer issues on various system configurations -Kiln length configuration in feet -Others -The increased minimum system specification -3D View required OpenGL 2.1 graphics adapter --------------------------------------------------------------------------------------------------- -- Version v6.0.3.2 - 27/01/2014 ------------------------------------------------------------------ --------------------------------------------------------------------------------------------------- - Major new release features - 4 Scanner support - Refractory Management (license needed) - 3D Visualisation Module (license needed) - Real continous view - Quick access to application manual ( press F1 ) - Extra statusbar information window - Hysteresis for low temperature alarm - Bugfixes - sometimes backups would fail or not executed at the right time - 3d topographical plot would fail if a pyrometer is below minimum thermograph temperature - stabilty fixes --------------------------------------------------------------------------------------------------- -- Version 5.6.1 - 27/05/2013 --------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - Installer: - Changed to SQL Server 2008 Express with .Net Framework 4 Beta 2 support --------------------------------------------------------------------------------------------------- -- Version 5.6.0 - 31/08/2012 --------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - ReadScan: - Small bug related to 2 scanner when it is active. --------------------------------------------------------------------------------------------------- -- Version 5.5.0 - 06/07/2012 --------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - General: - Included a manifest inside ReadScan in order to avoid problems with UAC in Windows 7 when registering and unregistering OPC Server. - Included a manifest inside Install in order to avoid problems with UAC in Windows 7 when installing SQL Server 2008. --------------------------------------------------------------------------------------------------- -- Version 5.5.0 - 27/04/2012 --------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - General: - Activated again the "CS Test Version document" - Activated the release concept --> updater pack size decreases enormously. - Config: - New option to "Kiln Options" directly under Main Manu --> Settings --> Kiln Settings - LRM window: in order to increase the precision of the LRM control, the precision is increased until the millimeters. - ReadScan: - Automatic trigger detection from scanner 1 and scanner 2 in order to avoid manual parameter configuration. - Deneb: - Add "Back to database" button for trend chart in "Internal temepratures", "Burning zones" and "LRM View". --------------------------------------------------------------------------------------------------- -- Version 5.4.6 - 07/12/2012 --------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - General: - For each delivered version, add in this file CSVersionHistory.txt detailing, more or less, the changes respect the previous delivered version. - Installer: - It's necessary administrator rights to install the system. - If default SQL port (1433) is in use, is not possible to install the system. - New warning added in the first screen : "If this computer should be accessed from others computers, user must be a member of a network domain!!" - Default showed Domain is the real domain, not the computer's name. - Only for Windows 7, folder where .ini files are saved is moved from "c:\Users\Public\Raytek\DataTempCS" to "C:\Users\Public\Documents\DataTempCS". - Is possible to create Update version of the installer (without the huge MSDE folder). - When updating: - The new folder with .ini files is also shared. - If it's not possible to connect with SQL Server, installer shows the next message: "Check state of SQL Server services, and the user for "SQL Server (Raytek)" service on Services console." - Icons: - When is xecuted, the next warning is showed: "Please, check the firewall on server computer. Port 1433 must be open in order all program can acces." - DBCHeck: - "Migrate old version" option: - Is possible to select between "Real Time" and "Historical Time". - Before migration, DBCheck warning about it's necessary database is empty, if it isn't. - "Empty database" option: - Is possible to select between "Real Time" and "Historical Time". - Before emptying database, DBCHeck warning about the convenience of create a backup copy before continue the process. - "Backup copies" option: Is possible to select between "Real Time" and "Historical Time". - "Setup memory" option: checked that it works properly. - The rest of programs: - Adapted in order to find, in Windows 7, the .ini files in the new folder "C:\Users\Public\Documents\DataTempCS". --------------------------------------------------------------------------------------------------- -- Version 5.4.5 - 17/01/2012 --------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - Installer: - It detects when SQLBrowser is disabled, changing its sttus and starting it. - The rest of programs: - It's possible to connect remotely: - from Windows XP to Windows 7 - from Windows 7 to Windows XP - from Windows 7 to Windows 7 --------------------------------------------------------------------------------------------------- -- Version 5.4.4.2 - 11/01/2012 ------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - ONLY ReadScan DELIVERED - Compatibility with FR and FA pyrometers. --------------------------------------------------------------------------------------------------- -- Version 5.4.4 - 21/11/2011 --------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - DBCHeck: - When migrating in Windows 7, corrected bug related to AdHocQuery component. - Config and ReadScan: - Chi with value different from 0 doesn't cause error. --------------------------------------------------------------------------------------------------- -- 5.4.3.0 - 19/10/2011 --------------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - Allowed aaximum size for database in function of SQL Server motor (2005 or 2008). --------------------------------------------------------------------------------------------------- -- 5.4.2.1 - 13/10/2011 --------------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - ONLY ReadScan DELIVERED - Allowed aaximum size for database in function of SQL Server motor (2005 or 2008). --------------------------------------------------------------------------------------------------- -- 5.4.2.0 - 14/09/2011 --------------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - Config: - Maximum length of kiln increased until 150 meters. --------------------------------------------------------------------------------------------------- -- 5.4.1.0 - 04/07/2011 --------------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - ONLY Config DELIVERED - Maximum internal temperature fo MI pyrometers increased until 120ºC --------------------------------------------------------------------------------------------------- -- 5.4.1.0 - 22/06/2011 --------------------------------------------------------------------------- --------------------------------------------------------------------------------------------------- - ReadScan and PCom: - Automatic search of correct baud rate when is not possible comunicate through a specific COM port and baud rate. - ReadScan: - When system is not synchronized, it doesn't crash when sending "unsynchronized image" to Deneb.