Views:

Below is a chart review which meters are compatible with the i1010 AC/DC current probe and the range they support. 

 

i1010 Clamp Compatibility Chart

 Output signal is 1mV AC per 1A ACOutput signal is 1mV DC per 1A DC
Model NumberSpecified AC Amperage RangeMeter Knob PositionSpecified DC Amperage RangeMeter Knob Setting
Fluke-15B1A to 600A ACVolts AC  use mV range up to 400A, and Volts AC 4V range for 400A to 600A1A to 1000A DCVolts DC mV  range up to 400A, and Volts DC  4V range for 400A to 1000A
Fluke-17B1A to 600A ACVolts AC  use mV range up to 400A, and Volts AC use 4V range for 400-600A1A to 1000A DCVolts DC mV  range up to 400A, and Volts DC  4V range for 400A to 1000A
Fluke-15B Max6A to 600A ACAC/DC mV  toggle yellow button1A to 1000A DCAC/DC mV  toggle yellow button up to 600A, and Volts DC use  6V range for 400A-1000A
Fluke-17B Max6A to 600A ACAC/DC mV  toggle yellow button1A to 1000A DCAC/DC mV  toggle yellow button up to 600A, and Volts DC use  6V range for 400A-1000A
Fluke-15B+4A to 600A ACAC/DC mV  toggle yellow button up to 400A, and Volts AC4V range for 400A to 600A1A to 1000A DCAC/DC mV  toggle yellow button up to 400A, and Volts DC use  4V range for 400A-1000A
Fluke-17B+4A to 600A ACAC/DC mV  toggle yellow button up to 400A, and Volts AC use  4V range for 400A to 600A1A to 1000A DCAC/DC mV  toggle yellow button up to 400A, and Volts DC use  4V range for 400A-1000A
Fluke-18B+4A to 600A ACAC/DC mV  toggle yellow button up to 400A, and Volts AC use  4V range for 400A to 600A1A to 1000A DCAC/DC mV  toggle yellow button up to 400A, and Volts DC use  4V range for 400A-1000A
     
Fluke-27-II1A to 600A ACVolts AC  use mV range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A
Fluke-28-II18A to 600A AC Volts AC  use mV range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A
Fluke-28-II EX18A to 600A AC Volts AC  use mV range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A 
     
Fluke-77-410A to 600A AC Volts AC  use 6V range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A
     
Fluke-83-51A to 600A AC Volts AC  use mV range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A
Fluke-87-518A to 600A AC Volts AC  use mV range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A
Fluke-87-5 MAX18A to 600A AC Volts AC  use mV range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A 
Fluke-88-51A to 600A AC Volts AC  use mV range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A 
     
Fluke-1016A to 600A ACVolts AC mV  range10A to 1000A DCVolts DC use  6V range
Fluke-1066A to 600A ACVolts AC mV  range10A to 1000A DCVolts DC use  6V range
Fluke-1076A to 600A ACVolts AC mV  range10A to 1000A DCVolts DC use  6V range
     
Fluke-11360A to 600A ACVolts AC 6V range60A to 1000A DCVolts DC 6V range
Fluke-1146A to 600A ACAC/DC mV  toggle yellow button1A to 1000A DCAC/DC mV  toggle yellow button up to 600A, and Volts DC use  6V range for 600A to 1000A 
Fluke-1156A to 600A ACAC/DC mV  toggle yellow button1A to 1000A DCAC/DC mV  toggle yellow button up to 600A, and Volts DC use  6V range for 600A to 1000A 
Fluke-1166A to 600A ACAC/DC mV  toggle yellow button1A to 1000A DCAC/DC mV  toggle yellow button up to 600A, and Volts DC use  6V range for 600A to 1000A 
Fluke-1176A to 600A ACAC/DC mV  toggle yellow button1A to 1000A DCAC/DC mV  toggle yellow button up to 600A, and Volts DC use  6V range for 600A to 1000A 
     
Fluke-17530A to 600A ACVolts AC  use mV range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A
Fluke-17730A to 600A ACVolts AC  use mV range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A
Fluke-17930A to 600A ACVolts AC  use mV range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A
     
Fluke-2336A to 600A ACAC/DC mV  toggle yellow button1A to 1000A DCAC/DC mV  toggle yellow button up to 600A, and Volts DC use  6V range for 600A to 1000A 
Fluke-2796A to 600A ACAC/DC mV  toggle yellow button1A to 1000A DCAC/DC mV  toggle yellow button up to 600A, and Volts DC use  6V range for 600A to 1000A 
     
Fluke-2871A to 600A AC Volts AC mV  range up to 500A, and Volts AC use  5V range for 500A to 600A1A to 1000A DCVolts DC mV  range up to 500A, and Volts DC use  5V range for 500A to 1000A
Fluke-2891A to 600A AC Volts AC mV  range up to 500A, and Volts AC use  5V range for 500A to 600A1A to 1000A DCVolts DC mV  range up to 500A, and Volts DC use  5V range for 500A to 1000A
     
Fluke-78720A to 600A ACVolts AC  use mV range up to 400A, and Volts AC  use 4V range from 400A to 600A1A to 1000A DCVolts DC mV  range up to 400A, and Volts DC use  4V range for 400A to 1000A 
Fluke-787B20A to 600A ACVolts AC  use mV range up to 400A, and Volts AC  use 4V range from 400A to 600A1A to 1000A DCVolts DC mV  range up to 400A, and Volts DC use  4V range for 400A to 1000A 
Fluke-78920A to 600A ACVolts AC  use mV range up to 400A, and Volts AC  use 4V range from 400A to 600A1A to 1000A DCVolts DC mV  range up to 400A, and Volts DC use  4V range for 400A to 1000A 
     
Fluke-157730A to 600A ACVolts AC  use mV range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A 
Fluke-1587 FC30A to 600A ACVolts AC  use mV range1A to 1000A DCVolts DC mV  range up to 600A, and Volts DC use  6V range for 600A to 1000A 
     
Fluke-3000 FC6A to 600A ACAC/DC mV  toggle yellow button1A to 1000A DCAC/DC mV  toggle yellow button up to 600A, and Volts DC use  6V range for 600A to 1000A