Views:

Fluke 2062 Advanced Wire Pro Tracer Product Resources
This article is to provide easy access to online resources for the Fluke 2062 Advanced Pro Wire Tracer. You will find links to useful resources for the 2062 Advanced Pro Wire Tracer below.


Introduction
The 2062 Advanced Wire Tracer is intended for quickly locating energized and de-energized wires in walls, ceilings and floors, finding breaks and opens in wiring, and locating breakers and fuses easily. Patented Smart Sensor™ locates and displays energized wires on the color display.
 

Quick Reference Guide
Quick Reference Guide
 

Users Manual
2062 Users Manual 
 

Additional Useful Documentation
Product Specifications
Safety Sheet
How Do Wire Tracers Work?
How To Trace Electrical Wires In Walls
 

Useful Videos
Fluke 2052 and 2062 Advanced Wire Tracers.

How to trace wire in walls with the Fluke 2052 and 2062 Advanced Wire Tracer.

How to ground the Fluke 2062 and 2052 Advanced Wire Tracer.



Specifications

Specifications: Fluke 2062 Advanced Pro Wire Tracer Kit

General2062R Receiver2000T Transmitteri400 AC Current Clamp
Measurement categoryCAT IV 600 VCAT IV 600 VCAT IV 600 V, CAT III 1000 V
Operating voltage600 V AC/DC600 V AC/DC1000 V AC
Operating frequencyEnergized: 6.25 kHz
De-Energized: 32.768 kHz
Energized/Loop: 6.25 kHz
De-Energized: 32.768 kHz
N/A
Signal indicationsNumeric, bar graph display and audible beepLEDs and audible beepN/A
Response timeSmart Sensor: 500 ms
Tip Sensor (Energized/De-Energized): 500 ms
NCV: 500 ms
Battery monitoring: 5 s
Line voltage monitoring: 1 s
Battery voltage monitoring: 5 s
N/A
Current output of signal (typical)N/AEnergized circuit:
High mode: 60 mA rms
Low mode: 30 mA rms

De-energized circuit:
High mode: 110 mA rms
Low mode: 40 mA rms
Loop mode with test leads: 160 mA rms
Loop mode with i400 AC Current Clamp:
385 mA rms
N/A
Signal voltage output (nominal)N/AEnergized circuit:
High mode: 14 W @ 230 V ac/50 Hz,
3.33 kΩ @ 230 V ac
Low mode: 4.6 W @ 230 V ac/50 Hz,
11.5 kΩ @ 230 V ac

De-energized circuit:
High mode: 31 V RMS, 140 Vp-p,
0.86 W @ 1 kΩ load
Low mode: 27.5 V RMS, 120 Vp-p,
0.1 W @ 1 kΩ load
Loop mode with test leads: 32 V RMS,
140 Vp-p, 0.87 W @ 1 kΩ load
Loop mode with i400 AC Current Clamp:
31 mV, 0.89 W @ 1 Ω load
N/A
Range detection (open air)Smart Sensor Direction Indication Mode
≤15 cm (6 in), 230 V AC,
high mode, sensitivity level 2

Tip Sensor: Energized
Max distance via air: up to 6.1 m (20 ft)
Pinpointing: approx. 5 cm (1.97 in)

Tip Sensor: De-Energized
Max distance via air: up to 4.5 m (14.7 ft)
Pinpointing: approx. 5 cm (1.97 in)

NCV (40 Hz to 400 Hz)
Max. sensitivity: 90 V up to 2 m
Min. sensitivity: 600 V up to 1 cm
 N/A
Current rangeN/AN/A400 A
Basic accuracyN/AN/A2 % + 0.06 A
(45 Hz to 400 Hz)
 
Display   
Display sizeLCD 89 mm (3.5 in)LEDsN/A
Display dimensions (W x H)70 mm x 52 mm (2.76 in x 2.07 in )N/AN/A
Display Resolution480 px x 320 pxN/AN/A
Display typeColor TFT LCDLEDsN/A
Display color16-bitOperating mode LEDs: red
Battery status LEDs: green, yellow, red
N/A
BacklightYesN/AN/A
 
Environmental   
Operating temperature-20 °C to 50 °C (-4 °F to 122 °F)-20 °C to 50 °C (-4 °F to 122 °F)-20 °C to 50 °C (-4 °F to 122 °F)
Operating humidity45%: -20 °C to <10 °C or 40 °C to 50 °C
(-4 °F to <50 °F or 104 °F to 122 °F)
95% (non-condensing): 10 °C to <30 °C
(50 °F to 86 °F)
75%: 30 °C to <40 °C (86 °F to <104 °F)
45%: -20 °C to <10 °C or 40 °C to 50 °C
(-4 °F to <50 °F or 104 °F to 122 °F)
95% (non-condensing): 10 °C to <30 °C
(50 °F to 86 °F)
75%: 30 °C to <40 °C (86 °F to <104 °F)
10 °C to <30 °C
(95 %: 50 °F to <86 °F)
30 °C to <40 °C
(75 %: 86 °F to <104 °F)
40 °C to <50 °C
(45 %: 104 °F to <122 °F)
Operating altitude2000 m (6561 ft)2000 m (6561 ft)2000 m (6561 ft)
Transient protectionN/A8.00 kV (1.2/50μS surge)N/A
Pollution degree222
IP ratingIP 40IP 40IP 40
Drop test1 m (3.28 ft)1 m (3.28 ft)1 m (3.28 ft)
 
Mechanical   
Power supply4 x AA (alkaline)8 x AA (alkaline)N/A
Power consumption (typical)110 mAHigh/low mode: 70 mA
Loop mode with Clamp: 90 mA
Consumption without signal
transmission: 10 mA
N/A
Battery lifeApprox. 20 hHigh/low mode: approx. 25 h
Loop mode: approx. 18 h
N/A
Low battery indicationYesYesN/A
FuseN/A1.6 A, 700 V, fast-acting,
Ø 6 x 32 mm, 50 kA interrupt
N/A
Maximum conductor sizeN/AN/A32 mm (1.26 in)
Dimensions (L x W x H)Approx. 277 x 112 x 65 mm
(10.92 x 4.43 x 2.55 in)
Approx. 183 x 93 x 50 mm
(7.2 x 3.66 x 1.97 in)
Approx. 150 x 70 x 30 mm
(5.9 x 2.75 x 1.18 in)
WeightApprox. 0.544 kg (1.20 lb)Approx. 0.57 kg (1.25 lb)Approx. 0.114 kg (0.25 lb)
 
Mechanical2000ACC Test Lead Accessory Kit
Includes2x 1 m test leads (red, black),
1x 7 m test lead (green),
2x test probes (black),
2x alligator clips (red, black),
2x outlet blade adapters (red, black),
2x outlet round adapters (red, black)
Measurement categoryCAT IV 600 V (test leads), CAT II 1000 V (test probes), CAT IV 600 V (alligator clips),
CAT II 300 V (outlet adapters)
Operating voltage and current600 V, 10 A max. (red/black leads), 600 V, 10 A max. (green lead), 1000 V, 8 A max. (black probe)
600 V, 10 A max. (alligator clips), 300 V, 10 A max. (outlet adapters)
Operating temperature0 °C to 50 °C (32 °F to 122 °F)
Operating humidity10 °C to <30 °C (95 %: 50 °F to <86 °F), 30 °C to <40 °C (75 %: 86 °F to <104 °F),
40 °C to <50 °C (45 %: 104 °F to <122 °F)
Storage temperature and humidity0 °C to 60 °C (32 °F to 140 °F), <95% (non-condensing)
Operating altitude2000 m (6561 ft)
Pollution degree2
Water and dust resistanceIP 20
Drop proof1 m (3.28 ft)
DimensionsRed/black leads: 1 m (3.28 ft), Green lead: 7 m (22.97 ft), Alligator clips: approx. 95 x 45 x 24 mm (3.74 x 1.77 x 0.94 in),
Outlet adapters: 72 x 18 x 18 mm (2.83 x 0.71 x 0.71 in)
WeightApprox. 0.4 kg (0.88 lb)