Views:

 

Example for setting the scanner internal sector 1 over the entire 90° FOV 

 

Configuring of alarm relay with 1s hold time

 

  1. SL1000       set 0 degrees FOV position in sector 1 
  2. SR1900       set 90 degrees FOV position in sector 1 
  3. SC12           find maximum in sector 1 
  4. TB10000    turn off the bottom alarm threshold 
  5. TT10150    alarm when result is greater or equal 150°C 
  6. TM11         set sector 1 to alarm for a time 
  7. TZ10010   time for holding alarm 001,0 sec 
  8. PS              writing the commands into the scanner internal EEPROM 

 

Special note: All commands must be in °C

 

The same settings are made also using the configurator: