Views:
Revision Date: 3/11/2026
Author: Tom Danaher
 
Issue: "Unable to export" error.
Causes:
-Measurements saved to 'modules' instead of string or harness (causes 'path' to exceed 256-character limit in Windows):
Measurement below needs to be recalled, then re-assigned and saved to the S1 location:
-Attempting to work with files in cloud or network locations instead of local folders
-long path between PVA Project file and exported folder location
 
Solutions, best practices:
-Create temporary 'master' folder on Desktop (i.e. "Project X PVA Master")
-put working or primary copy of PVA Project file in this master folder
-Export traces into this same folder
-Download & save the PVA-DAT file to this same folder
-Save PDF report into this same folder
 
The above steps also make it easier to update the report after adding measurements or correcting errors in the PVA project file.