Below is a list of meters that are compatible with the i410 AC/DC current probe and the levels they support.

 

i410 Clamp Compatibility Chart

 Output signal is 1mV AC per 1A ACOutput signal is 1mV DC per 1A DC
Model NumberSpecified AC Amperage RangeMeter Knob PositionSpecified DC Amperage RangeMeter Knob Setting
Fluke-15B1A to 400A ACVolts AC  use mV range1A to 400A DCVolts DC mV  range
Fluke-17B1A to 400A ACVolts AC  use mV range1A to 400A DCVolts DC mV  range 
Fluke-15B Max6A to 400A ACAC/DC mV  toggle yellow button1A to 400A DCAC/DC mV  toggle yellow button
Fluke-17B Max6A to 400A ACAC/DC mV  toggle yellow button1A to 400A DCAC/DC mV  toggle yellow button
Fluke-15B+4A to 400A ACAC/DC mV  toggle yellow button1A to 400A DCAC/DC mV  toggle yellow button 
Fluke-17B+4A to 400A ACAC/DC mV  toggle yellow button1A to 400A DCAC/DC mV  toggle yellow button
Fluke-18B+4A to 400A ACAC/DC mV  toggle yellow button1A to 400A DCAC/DC mV  toggle yellow button
     
Fluke-27-II1A to 400A ACVolts AC  use mV range1A to 400A DCVolts DC mV  range 
Fluke-28-II18A to 400A AC Volts AC  use mV range1A to 400A DCVolts DC mV  range 
Fluke-28-II EX18A to 400A AC Volts AC  use mV range1A to 400A DCVolts DC mV  range 
     
Fluke-77-410A to 400A AC Volts AC  use 6V range1A to 400A DCVolts DC mV  range 
     
Fluke-83-51A to 400A AC Volts AC  use mV range1A to 400A DCVolts DC mV  range 
Fluke-87-518A to 400A AC Volts AC  use mV range1A to 400A DCVolts DC mV  range 
Fluke-87-5 MAX18A to 400A AC Volts AC  use mV range1A to 400A DCVolts DC mV  range 
Fluke-88-51A to 400A AC Volts AC  use mV range1A to 400A DCVolts DC mV  range 
     
Fluke-1016A to 400A ACVolts AC mV  range10A to 400A DCVolts DC use  6V range
Fluke-1066A to 400A ACVolts AC mV  range10A to 400A DCVolts DC use  6V range
Fluke-1076A to 400A ACVolts AC mV  range10A to 400A DCVolts DC use  6V range
     
Fluke-11360A to 400A ACVolts AC 6V range60A to 400A DCVolts DC 6V range
     
Fluke-1146A to 400A ACAC/DC mV  toggle yellow button1A to 400A DCAC/DC mV  toggle yellow button
Fluke-1156A to 400A ACAC/DC mV  toggle yellow button1A to 400A DCAC/DC mV  toggle yellow button
Fluke-1166A to 400A ACAC/DC mV  toggle yellow button1A to 400A DCAC/DC mV  toggle yellow button
Fluke-1176A to 400A ACAC/DC mV  toggle yellow button1A to 400A DCAC/DC mV  toggle yellow button
     
Fluke-17530A to 400A ACVolts AC  use mV range1A to 400A DCVolts DC mV  range 
Fluke-17730A to 400A ACVolts AC  use mV range1A to 400A DCVolts DC mV  range 
Fluke-17930A to 400A ACVolts AC  use mV range1A to 400A DCVolts DC mV  range 
     
Fluke-2336A to 400A ACAC/DC mV  toggle yellow button1A to 400A DCAC/DC mV  toggle yellow button
Fluke-2796A to 400A ACAC/DC mV  toggle yellow button1A to 400A DCAC/DC mV  toggle yellow button
     
Fluke-2871A to 400A AC Volts AC mV  range1A to 400A DCVolts DC mV  range 
Fluke-2891A to 400A AC Volts AC mV  range1A to 400A DCVolts DC mV  range 
     
Fluke-78720A to 400A ACVolts AC  use mV range1A to 400A DCVolts DC mV  range 
Fluke-787B20A to 400A ACVolts AC  use mV range1A to 400A DCVolts DC mV  range 
Fluke-78920A to 400A ACVolts AC  use mV range1A to 400A DCVolts DC mV  range 
     
Fluke-157730A to 400A ACVolts AC  use mV range1A to 400A DCVolts DC mV  range 
Fluke-1587 FC30A to 400A ACVolts AC  use mV range1A to 400A DCVolts DC mV  range 
     
Fluke-3000 FC6A to 400A ACAC/DC mV  toggle yellow button1A to 400A DCAC/DC mV  toggle yellow button