Procedure to confirm correct signal generation and detection on the GFL-1500
 
Required: DC power source greater than 30Vdc. Example: 4 9V batteries connected in series
 
Set knob to Positive to Ground
 
Test #1 - Array mode
  1. Connect ground and positive test leads to Power source
  2. Check for lighting bolt symbol on screen
  3. Select Array mode
  4. Press Trace
  5. Confirm signal on Positive and Ground leads; no signal on Negative lead. Test using both the clamp and the receiver.
 
Test #2: - Unit mode
  • Connect positive and ground test lead dolphin clips together
  • Change mode to Unit mode
  • Press Trace
  • Confirm signal on Positive and Ground leads; no signal on Negative lead
 
Variations:
-Set knob to Negative to Ground, confirm signal on Negative and Ground test leads in Array mode (using DC battery power source), and Unit mode
-Turn knob to Map, test for signal on Positive and Negative